Abstract
Femoral shaft fractures in young patients generally result from high-energy trauma, and intramedullary nailing is currently the gold standard for the treatment of these fractures. Although various complications may develop after surgery, bending of the implanted nail as a result of a new fracture is uncommon and has been reported in the literature mainly in the form of case reports.
A 35-year-old man was brought to the emergency department with pain and an inability to walk following a motor vehicle collision. He reported that he had undergone surgery for a femoral shaft fracture at another center approximately 8 years earlier and had no other medical conditions. Initial examination revealed tenderness and ecchymosis of the thigh and deformity at the junction of the middle and distal thirds (Figure 1). No neurovascular deficit was detected. Anteroposterior and lateral radiographs of the femur showed bending of the intramedullary nail (IMN), with apex-posterior angulation at the junction of the middle and distal femoral diaphysis, and a refracture of the femur (Figure 2A and B). The patient was admitted to our clinic, informed about the treatment, and his consent was obtained. Routine preoperative tests and an anesthesia consultation were completed. Because a conventional nonlocking Küntscher nail had been used during the previous operation, revision surgery was planned after obtaining the appropriate nail extraction set.
Following spinal anesthesia and routine operative preparation, the fracture site was approached through the previous incision. The bent portion of the nail was identified. After a cortical window was created distally, the IMN was removed in a retrograde fashion by applying traction and rotation. Fibrous tissue formation was observed at the fracture site. The fibrous tissue was debrided, and the fracture ends were freshened. The cortical defect was filled with a corticocancellous autograft harvested from the iliac wing. After reduction, plate-and-screw osteosynthesis was performed. A locked IMN, which can also be used for more distal fractures, could have been used. However, because the fracture site had been opened to remove the bent nail and bone grafting had been performed, we considered plate-and-screw osteosynthesis to be more appropriate. Moreover, the presence of fibrous tissue at the fracture site and the use of the nail for a more distal fracture for which it was not appropriately indicated—conventional IMNs are generally recommended for shaft fractures because they lack a locking system—suggested that complete union might not have occurred and that the patient had probably been able to walk with a painless fibrous union before the refracture.
At the 1-year follow-up, fracture union had been achieved, and the patient was able to walk. Radiographs obtained 1 year postoperatively are shown in Figure 2C and D. This case was considered worthy of presentation, together with its clinical and radiographic images, because complications may develop when an IMN is used outside its appropriate indication, bending of the nail associated with refracture is rare, and revision surgery presents several technical challenges.
Figure 2. Femoral diaphyseal refracture and bending of the intramedullary nail (A and B); revision with plate-and-screw osteosynthesis at the 1-year follow-up (C and D).
Additional Information
Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.
Rights and Permissions
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/
About This Article
How to Cite This Article
Ahmet Özmeriç, Ahmet Aslan, Tolga Atay. Refracture and a bent intramedullary nail in a patient with a healed femoral fracture. J Clin Anal Med 2015;6(2):290-290. doi:10.4328/JCAM.1609
Publication History
- Received:
- 25.01.2013
- Accepted:
- 08.02.2013
- Published Online:
- 01.03.2015
- Printed:
- 01.03.2015