Letter to the Editor
I read with interest the article titled “Why and When Fiberoptic Bronchoscopy Fails,” by Demirer et al. 1, published on pages 31-34 of the second issue of The Annals of Eurasian Medicine in 2013. The investigators retrospectively reviewed the records of 1372 patients who underwent bronchoscopy and identified 66 complications occurring before or during bronchoscopy. Cardiac complications were identified in 18 patients. Hypertension, observed in 9 patients (50%), was emphasized as the most common cardiac complication. Hypertension is a chronic cardiovascular disease. Therefore, I do not consider it accurate to describe hypertension as a complication of fiberoptic bronchoscopy. The term “elevated arterial blood pressure” would have been more appropriate. The absence of information regarding whether these patients had preexisting hypertension, how and how frequently their blood pressure was monitored, whether antihypertensive medication was administered, and the levels of their systolic and diastolic blood pressures may be considered a limitation.
Respiratory complications were observed in 9 patients, and all were reported as hypoxia. I do not believe that the term “hypoxia” was used correctly because hypoxia refers to inadequate oxygen availability at the cellular level. The term “hypoxemia” should have been used instead. Moreover, hypoxemia was not defined in the presented study. Alamoudi et al. 2 defined hypoxemia as an oxygen saturation below 90% for longer than 10 seconds. Based on this definition, it is unclear how many episodes of hypoxemia occurred during bronchoscopy. I also consider the absence of information regarding comorbid conditions that may facilitate the development of hypoxemia, such as chronic obstructive pulmonary disease and interstitial lung disease, to be a limitation. Furthermore, it appears that no respiratory complications other than hypoxemia occurred. This finding does not seem entirely convincing. Numerous studies on this subject have described complications such as laryngospasm, bronchospasm, and biopsy-related hemorrhage 3,4.
The indications for bronchoscopy, the diagnoses established after bronchoscopy, and the accompanying comorbid conditions were not reported in the article. Without information regarding how many of the 1372 patients who underwent bronchoscopy were diagnosed with cancer, the statement that respiratory complications were more common among patients with cancer may not accurately reflect the actual findings.
In conclusion, terminological errors and insufficient patient data are apparent in the article presented by Ersin et al. 1. These limitations reduce the strength of the study.
Additional Information
Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.
Rights and Permissions
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/
About This Article
How to Cite This Article
Aziz Gümüş. The “when and why” behind failure of a fiberoptic bronchoscopy. J Clin Anal Med 2015;6(2):284-284. doi:10.4328/JCAM.2073
Publication History
- Received:
- 29.09.2013
- Accepted:
- 01.10.2013
- Published Online:
- 01.03.2015
- Printed:
- 01.03.2015