AimA three-day diet in bowel preparation before undergoing colonoscopy is an important factor that affects patient compliance. This study aimed to compare the effectiveness of sodium picosulfate/magnesium citrate without a diet and rectal enema application protocol and conventional sennoside protocol before colonoscopy.MethodsThis is a prospective, single-centre, investigator-blinded, randomized study. A total of 60 patients were recruited: 30 in the sennoside group and 30 in the sodium picosulfate/magnesium citrate group. All procedures were performed by an experienced endoscopist who was blinded to the bowel preparation protocol. The Ottawa Bowel Preparation Scale was used by the endoscopist to assess the bowel preparation state.ResultsThe effectiveness of bowel cleansing regimens was similar in the entire, right, transverse, descending, and rectosigmoid colon according to the Ottawa Bowel Preparation Scale (P > .05). There was no difference between the groups in terms of cecal intubation rates, the detection of polyps, and the number of polyps.ConclusionThe use of sodium picosulfate/magnesium citrate is an effective bowel cleansing agent and can provide both successful colonoscopy and patient compliance without a three-day fiber-free diet.

Keywords

bowel preparationsodium picosulfate/magnesium citratediet-free colonoscopysennoside

Introduction

Colonoscopy is a widely used procedure for diagnosing and treating colon and terminal ileum pathologies. Adequate bowel cleansing is essential for the detailed visualization of the mucosa of the entire large intestine and the quality of the colonoscopy procedure.1
An ideal bowel preparation method should be effective in cleansing the bowel and be well tolerated by the patients. Factors that adversely affect patient compliance are the need for a three-day diet and high fluid intake during the bowel cleansing process, unexpected symptoms such as abdominal pain, vomiting, cramps after drug intake, and enema applications. Polyethylene glycol (PEG), sodium phosphate, and sennoside group drugs are commonly used for bowel cleansing before colonoscopy. Although PEG is seen as the gold standard in bowel cleansing, some patients cannot tolerate it well due to its taste and need for high volume ingestion.2 Sodium phosphate group agents are a better option in terms of patient compliance, but they bring concerns due to possible negative adverse effects.3,4 In our country, sennoside and sodium phosphate groups are frequently used for colon preparation and these protocols require a three-day diet and enema application.
The sodium picosulfate/magnesium citrate (SMPS) protocol is a well-tolerated intestinal cleansing agent due to low volume fluid requirement and good taste. The European Gastrointestinal Endoscopy Association.5 recommends SPMS as an alternative to PEG solutions because of its less frequent adverse effects and an equivalent colon cleansing rate. The effects of sodium picosulfate/magnesium citrate agents on bowel cleansing in both classic protocols and divided doses have been compared in many studies.6-8 However, we found no study in the literature that evaluated the effects of SMPS agents on bowel cleansing without a fiber-free diet.
The aim of our study was to compare the effectiveness of the SPMS protocol, which is used without diet and enema, and the sennoside protocol, which requires a three-day diet and a rectal enema for bowel preparation before colonoscopy.

Materials and Methods

This was a prospective, single-center, investigator-blinded, randomized study evaluating the effect of two different bowel preparation protocols on adequate bowel preparation. Our study was conducted in accordance with the ethical standards of the World Medical Association Helsinki Declaration Principles. This study was approved by the KTO Karatay University Medical Faculty Ethics committee (approval number: 2021/035).PatientsThe study included patients aged 18-80 years who presented to the general surgery outpatient clinic due to colorectal cancer screening or nonspecific gastrointestinal symptoms between January and April 2021. Exclusion criteria were pregnancy or breastfeeding, history of colon resection, intestinal obstruction, presence of serious comorbid diseases (e.g. heart, kidney and hepatic failure), presence of psychiatric disease, and unwillingness to participate in the study. Written informed consent was obtained from all patients who agreed to participate in the study. Before the colonoscopy procedure, patient information including age, sex, colonoscopy indications, previous surgery, and colonoscopy procedures were collected.RandomizationThe participants were enrolled by a clinical coordinator nurse. The coordinator nurse randomly assigned the patients into two bowel preparation protocol groups (1:1) according to the order of patient arrival. Numbered sealed envelopes were used to ensure confidentiality of distribution. The endoscopists and researchers were unaware of the distribution of the groups. The diet protocols and the bowel cleaning agents to be used were explained to each patient in detail by the coordinator nurse. The patients were advised not to ask any questions or give information to the endoscopists and the endoscopy staff about the bowel preparation protocol.ProtocolPatients in the first group (sennoside group) were given a list of foods they could and could not eat, and a clear diet was recommended for three days before the colonoscopy. Patients were told to drink a total of 500 ml sennoside solution (250 mL X-M Diet Solution Laxative® (containing 0.5 g Sennosid A + B calcium), Yenişehir, Turkey) 250+250 mL the day before the colonoscopy, at 14:00 and 18:00 PM. Patients were also warned to apply a total of two bottles of 210 mL rectal enema (B.T. enema® 210 mL, Mediterranean Lab Tic. Ve San CO., LTD, Ankara, Turkey) the night before the colonoscopy at 22.00 PM and in the morning of the procedure at 08.00 AM. Patients in the second group (SPMS group) were given two sachets of SPMS, each containing sodium picosulfate (10 g), magnesium oxide (3.5 g) and citric acid (12 g) (Picoprep®, Ferring Arzneimittel Ges.mbH, Vienna, Austria). They were told to prepare each sachet by mixing it with 150 mL of water and to drink it at 16:00 PM and 22:00 PM on the day before the colonoscopy procedure. Patients were also advised to consume at least five glasses of water after each solution. The patients in this group did not receive a rectal enema.
Patients in both groups were instructed to consume clear liquids such as water or tea, until the consistency and color of the stool became like water until 24:00 PM. Patients were advised to have a liquid diet breakfast on the morning of the colonoscopy. All colonoscopies were performed between 13:00 PM and 18:00 PM.ProcedureAll colonoscopy procedures were performed under propofol-based sedation. A Fujinon System 4400XI© (Fujinon Inc, Tokyo, Japan) colonoscopy device was used in the procedures. During the colonoscopy, the patients’ blood pressure, heart rate, and peripheral oxygen saturation were monitored, and their stability was ensured. All procedures were performed by an experienced endoscopist who was blinded to the bowel preparation method. The quality of bowel cleansing was scored by the endoscopist immediately after colonoscopy according to the Ottawa Bowel Preparation Scale (OBPS), which is scored from 0 to 4 (Table 1).9 The adequacy of colon cleansing was evaluated both as the entire colon and separately (ascending, transverse, descending, and rectosigmoid colon) according to the OBPS. In OBPS scores, 3 and 4 are accepted as insufficient bowel cleansing. In addition, the data of whether cecal intubation was performed, detection of polyps, and the number of detected polyps were added to the form. The data from the colonoscopies were written on a form and put in a sealed envelope and handed over to the coordinator nurse.Statistical AnalysisIn statistical calculations, the mean, standard deviation, median, lowest, highest, and ratio values were used. The distribution of variables was measured using the Kolmogorov-Smirnov test. The Mann-Whitney U test was used to compare numerical variables between groups. The Chi-square or Fisher’s exact test was used to compare categorical variables. Statistical analyses were performed using the IBM SPSS Statistics for Windows, Version 21.0 software package (2012 Armonk, NY: IBM Corp). The level of statistical significance was accepted as P < .05.

Results

A total of 67 patients were included in the study. Seven patients (three in the sennoside group and four in the SPMS group) whose colonoscopies could not be completed were excluded from the study. Accordingly, 60 patients (30 in the sennoside group and 30 in the SPMS group) were included in the study. The mean age of the patients was 49.31 ± 17.70 (range, 20-80) years, and 56.7% were male. There were no significant differences between the groups in terms of age, sex, and colonoscopy indication (P = .344, P = .435, and P = .264, respectively, Table 2). Most (65%) of the patients were referred to colonoscopy because of nonspecific gastrointestinal symptoms. In the SPMS group, more colonoscopies were performed for colorectal cancer screening (40% vs. 30%), whereas in the sennoside group, more colonoscopies were performed for gastrointestinal symptoms (70% vs. 60%).
All patients were able to tolerate both protocols. The most common problem in the sennoside group was enema intolerance, but this was not observed in the SPMS group because the patients did not receive a rectal enema. The most common adverse effect in both groups was abdominal pain. The number of patients with adverse effects was similar in both groups (P = .532).
The intestinal cleansing results are summarized in Table 3. Although the number of patients with adequate bowel cleansing in the entire colonoscopy evaluation was slightly higher in the sennoside group, there was no statistically significant difference between the groups (83.3% vs. 76.7%, respectively, P = .748). The mean OBPS scores were 1.46 ± 1.07 in the sennoside group and 1.43 ± 1.27 in the SPMS group and were similar between the two groups (P = .903). Regarding bowel preparation scores for the entire colon and each colon segment separately (ascending, transverse, descending, and rectosigmoid colon), there was no significant difference between the groups.
The cecal intubation rate was higher in the SPMS group than in the sennoside group, but the difference was not statistically significant.[25(83.3%) vs. 21(70%), P = .360] In addition, although fewer patients were detected to have polyps in the SPMS group, the average number of polyps detected was relatively higher than in the sennoside group. There was no significant difference between the groups in terms of the number of patients with polyps detected, and the average number of polyps (P = .596, P = .454, respectively).

Discussion

In this prospective study, the efficacy of the classic sennoside protocol with a fiber-free diet for 3 days and SPMS solutions without diet on intestinal cleansing was evaluated. It was observed that the use of SPMS without dieting and the use of sennoside with a 3-day diet and rectal enema in preparation for colonoscopy yielded similar results. In addition, we found that rectal enemas caused discomfort to patients and more adverse effects were observed with the sennoside protocol.
Although the purpose of an ideal bowel cleansing method is to remove all fecal material sufficiently to clearly evaluate pathologic lesions, patient compliance with intestinal cleansing agents should not be ignored. Polyethylene glycol is accepted as the gold standard in bowel cleansing, but the need for a fiber-free diet and plenty of fluid consumption makes patient compliance difficult and unsuccessful bowel cleansing results can be seen.10 Indeed, many studies have been conducted comparing the effects of protocols involving PEG,10-12 Na-P,10,13 SMPS.11,14 and sennoside.12-14 agents. In most protocols, due to the negative aspects (3-day diet and bad taste of the agents), patient compliance problems are at high levels. This situation has led physicians to look for protocols that both provide effective bowel cleansing and increase patient compliance.
The pre-colonoscopy diet type is crucial for bowel cleansing, but surprisingly few studies have been conducted on this topic. Among the risk factors for inadequate bowel cleansing, dietary restriction is often seen as an integral component of bowel preparation, but can sometimes be overlooked. Current guidelines recommend the use of a low-fiber diet in addition to a full liquid diet the day before the colonoscopy.15
Although most patients state that they understand their fiber diet and laxative practices, less than 20% follow a low fiber diet and approximately 75% follow a clear liquid diet only one day before the colonoscopy.16
Therefore, it is becoming increasingly important to develop intestinal cleansing protocols that do not require a diet. The taste of the agents used and the adverse effects related to the drug also affect compliance.3 For this reason, besides acceptable bowel cleansing, there is a need for a bowel preparation protocol that is easy to drink, requires less dieting, and has minimal drug-related adverse effects.
Sodium picosulfate/magnesium citrate solutions are becoming more popular in colonoscopy preparation. Similar or even better bowel cleansing results have been reported, especially when compared with PEG solutions. It has been reported in many studies that there is better patient compliance with this protocol due to its better taste and lack of need for large amounts of fluid intake.15,17-20 We compared the use of diet-free SPMS with the sennoside protocol, which is widely used in our country. To our knowledge, the current study is the first randomized, prospective clinical study to investigate the effect of diet liberalization (diet free vs. clear liquid diet) during bowel preparation using SPMS in colonoscopy in healthy outpatients. Furthermore, our study had several distinct advantages over previous studies. Our study compared polyp detection and cecal intubation rates, which are accepted as important quality indicators for colonoscopy, as well as bowel cleansing quality between the two study groups. Similar results were obtained in a study comparing SPMS and sennoside agents; however, no dietary restriction was applied in the use of either agent.14 In our study, no difference was found between the two protocols when we compared rates of both individual colon segments, entire colon cleansing assessments, and polyp detection rates (Table 3). Also, the rates of adverse effects were similar (P = .532). The most important limitation of our study was the small number of patients. We planned our study as a preliminary study because there was no previous experience with the dietless SPMS protocol. Satisfactory results will encourage this prospective study to be strengthened by larger series.

Conclusion

According to the preliminary results of this study, the use of the SPMS protocol without dieting provides high patient compliance and sufficient bowel cleansing equivalent to the sennoside protocol. If our results are confirmed in larger series, the use of SPMS without a diet protocol could be considered the preferred bowel cleansing protocol.

Declarations

Animal and Human Rights Statement

All procedures performed in this study were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. No animal or human studies were carried out by the authors for this article.

Data Availability

The datasets used and/or analyzed during the current study are not publicly available due to patient privacy reasons but are available from the corresponding author on reasonable request.

Conflict of Interest

None of the authors received any type of financial support that could be considered potential conflict of interest regarding the manuscript or its submission.

Funding

None.

Acknowledgements

Thank you to Akif ALTINBAS for his contibutions.

References

  1. Beck DE. Bowel preparation for colonoscopy. Clin Colon Rectal Surg. 2010;23(1):10-13. doi:10.1055/s-0030-1247851
  2. Hookey LC, Vanner S. A review of current issues underlying colon cleansing before colonoscopy. Can J Gastroenterol. 2007;21(2):105-111. doi:10.1155/2007/634125
  3. Tan JJ, Tjandra JJ. Which is the optimal bowel preparation for colonoscopy? A meta-analysis. Colorectal Dis. 2006;8(4):247-258. doi:10.1111/j.1463-1318.2006.00970.x
  4. Yoshioka K, Connolly AB, Ogunbiyi OA, Hasegawa H, Morton DG, Keighley MR. Randomized trial of oral sodium phosphate compared with oral sodium picosulphate (Picolax) for elective colorectal surgery and colonoscopy. Dig Surg. 2000;17(1):66-70. doi:10.1159/000018802
  5. Hassan C, Bretthauer M, Kaminski MF, Polkowski M, Rembacken B, Saunders B, et al. Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) guideline. Endoscopy. 2013;45(2):142-150. doi:10.1055/s-0032-1326186
  6. van Lieshout I, Munsterman ID, Eskes AM, Maaskant JM, van der Hulst R. Systematic review and meta-analysis: sodium picosulphate with magnesium citrate as bowel preparation for colonoscopy. United European Gastroenterol J. 2017;5(7):917-943. doi:10.1177/2050640616684696
  7. Jin Z, Lu Y, Zhou Y, Gong B. Systematic review and meta-analysis: sodium picosulfate/magnesium citrate vs polyethylene glycol for colonoscopy preparation. Eur J Clin Pharmacol. 2016;72(5):523-532. doi:10.1007/s00228-016-2013-5
  8. Schulz C, Müller J, Sauter J, Miehlke S, Schmöcker C, Hartmann D, et al. Superiority of a split-dose regimen of sodium picosulfate/magnesium citrate (SPMC) in comparison with a prior-day schedule (AM/PM) for colonoscopy preparation: a randomized single-blinded study. J Gastrointestin Liver Dis. 2016;25(3):295-302. doi:10.15403/jgld.2014.1121.253.mag
  9. Rostom A, Jolicoeur E. Validation of a new scale for the assessment of bowel preparation quality. Gastrointest Endosc. 2004;59(4):482-486. doi:10.1016/s0016-5107(03)02875-x
  10. Cheng J, Tao K, Shuai X, Gao J. Sodium phosphate versus polyethylene glycol for colonoscopy bowel preparation: an updated meta-analysis of randomized controlled trials. Surg Endosc. 2016;30(9):4033-4041. doi:10.1007/s00464-015-4716-6
  11. Mathus-Vliegen EMH, van der Vliet K, Wignand-van der Storm IJ, Stadwijk JS. Split-dose bowel cleansing with picosulphate is safe and better tolerated than 2-L polyethylene glycol solution. Eur J Gastroenterol Hepatol. 2018;30(7):709-717. doi:10.1097/meg.0000000000001120
  12. Terry NA, Chen-Lim ML, Ely E, Jatla M, Ciavardone D, Esch S, et al. Polyethylene glycol powder solution versus senna for bowel preparation for colonoscopy in children. J Pediatr Gastroenterol Nutr. 2013;56(2):215-219. doi:10.1097/mpg.0b013e3182633d0a
  13. Manukyan MN, Tolan K, Severge U, Attaallah W, Kebudi A, Cingi A. Prospective randomized comparison of oral sodium phosphate and sennoside A+B calcium lavage for colonoscopy preparation. Surg Laparosc Endosc Percutan Tech. 2011;21(2):90-93. doi:10.1097/sle.0b013e31820e8793
  14. Demeter P, Ujszászy L, Sike R, Tóth GT, Grenda A, Kiss GG, et al. Comparison of the effectiveness and tolerability of the saccharosum-sennosid-B solution and sodium picosulfate in preparation for colonoscopy: prospective, multicenter, randomized study. Orv Hetil. 2003;144(32):1587-1590.
  15. Johnson DA, Barkun AN, Cohen LB, Dominitz JA, Kaltenbach T, Martel M, et al. Optimizing adequacy of bowel cleansing for colonoscopy: recommendations from the US Multi-Society Task Force on Colorectal Cancer. Gastrointest Endosc. 2014;80(4):543-562. doi:10.1016/j.gie.2014.08.002
  16. Leszczynski AM, MacArthur KL, Nelson KP, Schueler SA, Quatromoni PA, Jacobson BC. The association among diet, dietary fiber, and bowel preparation at colonoscopy. Gastrointest Endosc. 2018;88(4):685-694. doi:10.1016/j.gie.2018.06.034
  17. Jeon SR, Kim HG, Lee JS, Kim JO, Lee TH, Cho JH, et al. Randomized controlled trial of low-volume bowel preparation agents for colonic bowel preparation: 2-L polyethylene glycol with ascorbic acid versus sodium picosulfate with magnesium citrate. Int J Colorectal Dis. 2015;30(2):251-258. doi:10.1007/s00384-014-2066-9
  18. Kim HG, Huh KC, Koo HS, Kim SE, Kim JO, Kim TI, et al. Sodium picosulfate with magnesium citrate (SPMC) plus laxative is a good alternative to conventional large-volume polyethylene glycol in bowel preparation: a multicenter randomized single-blinded trial. Gut Liver. 2015;9(4):494-501. doi:10.5009/gnl14010
  19. Leitao K, Grimstad T, Bretthauer M, Holme Ø, Paulsen V, Karlsen L, et al. Polyethylene glycol vs sodium picosulfate/magnesium citrate for colonoscopy preparation. Endosc Int Open. 2014;2(4). doi:10.1055/s-0034-1377520
  20. Muñoz-Navas M, Calleja JL, Payeras G, Hervás AJ, Abreu LE, Orive V, et al. A randomized trial to compare the efficacy and tolerability of sodium picosulfate-magnesium citrate solution vs 4-L polyethylene glycol solution as a bowel preparation for colonoscopy. Int J Colorectal Dis. 2015;30(10):1407-1416. doi:10.1007/s00384-015-2307-6

Tables

Table 1. Bowel cleansing assessment scale (ottawa bowel preparation scale)

Table 2. Demographic data of patients according to bowel preparation protocols

M: mean SD: standard deviation n: number of patients

Table 3. Bowel cleansing data

* Ottowa bowel preparation scale, SPMC: Sodium picosulfate-magnesium citrate. SD: Standard deviation

Additional Information

Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.

Rights and Permissions

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/

About This Article

How to Cite This Article

Ramazan Saygın Kerimoğlu, Süleyman Kargın, Alpaslan Şahin. Effectiveness of sodium picosulfate/magnesium citrate without diet versus sennoside with diet in bowel preparation. Ann Clin Anal Med 2022;13(6):592-596. doi:10.4328/ACAM.20810

Publication History

Received:
07.08.2021
Accepted:
18.04.2022
Published Online:
27.04.2022
Printed: