Abstract
AimIn this study, cyclic fatigue resistance of Reciproc R25, Golden Star RC, NIC RC, and RO files were compared. The present study aimed to compare the cyclic fatigue strength of the original RC files and their equivalent GS, NIC, and RO files.MethodsIn this study, 100 files, 25 in each group, were subjected to cyclic fatigue test on the artificial canal on stainless steel block with 60° curvature, 5 mm radius, and 1.5 mm depth. The files in all groups were rotated until they were broken in the artificial canal using the Reciproc ALL program. The time to break was recorded with a 1/100 second precision stopwatch for each file and the total number of rounds was calculated. Number of rounds of files and the lengths of fractures were recorded then evaluated statistically (P < .05). The files were examined by scanning electron microscopy (SEM) images to evaluate the fracture type.ResultsAs a result of the data obtained from the study, the RC file was statistically the most resistant to cyclic fatigue (P < .05). GS and NIC files were found to be more resistant than RO (P < .05).ConclusionBased on the data derived from this study, it is evident that the RC file exhibited the highest cyclic fatigue resistance, as indicated by statistically significant results. In comparison, GS and NIC files displayed greater resistance to cyclic fatigue than RO files. The examination of SEM images further corroborated the presence of cyclic fatigue fractures in the tested files. Notably, GS, NIC, and RO files, despite sharing a similar shape with the RC, failed to match the original RC file’s level of resistance against cyclic fatigue, underscoring the importance of considering file composition and heat treatment in enhancing resistance.
Keywords
Introduction
Today, nickel-titanium rotary instruments (NiTi) are often used for mechanical instrumentation of root canals. NiTi files have gained popularity due to their lower incidence of complications, such as zipping, stepping, and perforation, compared to traditional stainless steel files.1-2 Despite the advantages of NiTi files, the risk of fracture should be considered by clinicians, especially in curved root canals.3 A broken NiTi instrument in the root canal system adversely affects the success of root canal treatment (RCT). The main reasons for breaking NiTi files are cyclic fatigue and torsional fatigue.4-5 In cyclic fatigue, a specific area of NiTi files is subjected to compression and tensile forces in each cycle and eventually breaks.6
Recently, several methods have been developed to increase the cyclic fatigue resistance of NiTi rotary files, such as various heat treatments, different cross-sectional designs, and application of surface electro polishing processes.7 According to a previously presented study,8 it has been reported that root canals can be enlarged by a single file with reciprocal motion. The kinematics of the file in a reciprocal motion are clockwise and counterclockwise. It has been found that reciprocal motion causes the resistance of the files to increase.9-10
The Reciproc (VDW) motion is widely used to shape root canals in the clinic. Many studies have reported the superior ability of this system to root canal treatment11 and retreatment.12-13 The original Reciproc (RC; VDW, Munich, Germany) file has M-Wire technology and is reported to have a very high cyclic resistance with reciprocal motion.14-16 The Reciproc file is reported to be in austenitic phase during clinical use.17
The original Reciproc R25, which is planned to be used in the study, and its equipollent productions are Golden Star RC 25 (GS; Golden Star LTD, Shenzhen, China), NIC RC 25 (NIC; Superline Technology, Shenzhen, China), and Recip-One (RO; Rogin Medical LTD, Shenzhen, China) root canal files. In the literature, there is no study that compares the RC file’s cyclic fatigue resistance with its equipollents (GS, NIC, and RO). The purpose of the study is to compare the cyclic fracture resistance between RC files and its equipollents GS, NIC, and RO files. The null hypothesis of the study is that the cyclic fatigue resistance of the original RC file resides in the same cyclic resistance as equipollent GS, NIC, and RO files.
Materials and Methods
Stainless steel artificial root canal with a 5 mm radius, 1.5 mm depth, and a 60° curvature were used described in the present study as a previous study.6 In accordance with the limitations of the study, each type of NiTi file was used as a group. In the study, a total of 4 groups of 100 files was examined with a stereo microscope (SMZ1500, Nikon Corp., Tokyo, Japan), and damaged and/or deformity files were replaced with new ones. NiTi file types were tested. RC R25 and its equipollent production were selected as GS 25, NIC 25, and RO 25 (n = 25). The root canal files were tested in the “Reciproc All” program with the 6:1 reductive VDW Silver Reciproc endodontic motor (VDW). In order to reduce friction during the experiments, lubricant oil (WD-40, Milton Keynes, England) was used in the artificial root canal. The rotational time of the file in the artificial root canal was measured by stopwatch until it was broken (Fig. 1). Then, the rotational times until break were calculated in seconds and multiplied by the number of turns per second, and the number of cyclic failure (NCF) was found. The number of rounds per minute was calculated by the manufacturer to claim 300 rpm for the “Reciproc All” program. As a result of cyclic fatigue, the fractures of the files were measured by means of calipers to determine whether the areas affected by the cyclic force were the closest to each other. After the cyclic fatigue test, 8 pieces of fractured files (2 pieces from each group) were observed using a scanning electron microscope (SEM) (Zeiss Supra 40VP, Carl Zeiss SMT Inc., Oberkochen, Germany) to determine the fracture types under 500X and 3000X magnification.Ethical ApprovalThis study was approved by the Ethics Committee of Pamukkale University (Date: 17.08.2023, Decision No: E-60116787-020-406510).Statistical AnalysisAll statistical analyses were performed using SPSS 24.0 (SPSS Inc., Chicago, IL, USA). Shapiro–Wilk tests were used for testing normality. Group comparisons were conducted through the utilization of analysis of variance (ANOVA) followed by posthoc Tukey tests. P value <.05 was considered statistically significant.
Results
The cyclic fatigue resistance of the original RC file was found to be significantly higher than the equipollents GS, NIC, and RO files (P < .05). While there was no statistically difference between NIC and GS files in terms of cyclic fatigue resistance, the resistance of RO file was statistically significantly lower than NIC and GS files (P < .05, Table 1).
There was no significant difference in the mean length of the fractured parts (Table 1), so that the fragments exposed to compression and tensile forces were identical. SEM analysis of the fractured surfaces of the files have typical cyclic fatigue crack origins (Figure 2).
Discussion
In the present study, the cyclic fatigue resistance simulations of the RC file were compared with GS, NIC, and RO files. Files were tested in a 5 mm diameter artificial canal with a 60° curve angle. In this study, when the lengths of the broken parts were examined, no statistically significant difference was found between the lengths of the parts. This finding shows that the files tested are in a standard position in the artificial canal and that the area from which the force comes corresponds to the same region.18 It has been reported that the reciprocal motion increases the resistance of the files against cyclic fatigue considerably.9,14 In this study, the files using with reciprocal motion were compared with each other. According to statistical data, the cyclic resistance of the original RC file was found to be significantly better than its equipollents GS, NIC, and RO files. As a result of the presented study, the null hypothesis was rejected. The use of NiTi files with endodontic motors in the shaping of the root canals shortened the treatment process and also reduced the complications during the treatment (perforations, change working length, apical transportation).19
During RCT, root canal files broken during instrumentation of the root canals adversely affect the success of the treatment. The main causes broken of root canal files are torsional and cyclic fatigue.19 The cyclic fatigue resistance of the files, which have been used in the present study, was compared. Root canal files generally work with 2 kinds of motion. The first is a continuous rotation motion, which has a continuous clockwise rotation movement while the second is the reciprocating motion, which is clockwise and counterclockwise at various angles. In previous studies,9,14 it has been observed that the resistance of the files at curved canals with reciprocal motion increases significantly. It is also reported that RC files have higher resistance than classic files such as Mtwo and ProTaper although they have similar cross section.20 In the literature, there is no study that compares RC files resistance with its own equipollents. While GS and NIC files in the semi-martensitic phase with heat treatment, the RO file is made of super-elastic NiTi alloy which has not been heat treated. Heat treated files such as GS and NIC, which are close to the gold color, have been very popular lately, and many studies have been done about these type files.21 Almost all of these studies, which are also called gold alloy, have been reported to increase the resistance of the files to the fracture as a result of the heat treatment they are subjected to after shaping the files.22-24
In the present study, it was found that the heat treated GS and NIC files, which are called gold alloys, were found to have statistically less cyclic fatigue resistance compared to the RC file which was not heat treated and only called M-Wire (P < .05). This result is not compatible with previous studies22-24 for heat-treated files. This is because GS and NIC files are produced as equipollents of RC files, and they do not belong to a recognized company and that the quality of production is lower. However, when the equipollent production files are compared among themselves, the cyclic fatigue resistance of the RO file, which is only super elastic, is statistically lower than the heat treated GS and NIC files.22-24 The results of the tests showed that the lengths of the broken file parts were very close to each other, indicating that the regions where the cyclic fatigue intensity was the same, so that the metal volumes affected were close to each other.
Conclusion
In the present study, the RC file have statistically the highest cyclic fatigue resistance, and the RO file has the lowest. However, performances of GS and NIC files cannot be considered bad. Notably, while GS, NIC, and RO files share a similar shape with the RC file, they fall short of replicating its original level of resistance against cyclic fatigue. This emphasizes the significance of considering file composition and heat treatment in enhancing cyclic fatigue resistance.
Declarations
Animal and Human Rights Statement
All procedures performed in this study were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Data Availability
The datasets used and/or analyzed during the current study are not publicly available due to patient privacy reasons but are available from the corresponding author on reasonable request.
Conflict of Interest
The authors declare that there is no conflict of interest.
Funding
This study was supported by Pamukkale University-BAP-HZD program (2019HZDP003).
Acknowledgements
This project, labeled 2019HZDP003, was supported by Pamukkale University Scientific Research Projects Unit . I would like to thank Hande ŞENOL for her contributions to the statistical analysis of the data.
References
- Langaliya AK, Kothari AK, Surti NR, Patel AR, Doshi PR, Pandya DJ. In vitro comparative evaluation of dentinal microcracks formation during root canal preparation by different nickel-titanium file systems. Saudi Endod J. 2018;8(3):183-188. doi:10.4103/sej.sej_23_17
- Cheung GS. Instrument fracture: mechanisms, removal of fragments, and clinical outcomes. Endod Topics. 2007;16(1):1-26. doi:10.1111/j.1601-1546.2009.00239.x
- Orhan EO, Ertuğrul İF, Tosun S. Monotonic torsional resistance and fatigue resistance of novel SCOPE RS instruments. Microsc Res Tech. 2021;84(1):62-70. doi:10.1002/jemt.23565
- Pedullà E, Lo Savio F, Boninelli S, et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42(1):156-159. doi:10.1016/j.joen.2015.10.004
- Gambarini G, Cicconetti A, Di Nardo D, et al. Influence of different heat treatments on torsional and cyclic fatigue resistance of nickel-titanium rotary files: a comparative study. Appl Sci. 2020;10(16):5604. doi:10.3390/app10165604
- Gambarini G, Grande NM, Plotino G, et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod. 2008;34(8):1003-1005. doi:10.1016/j.joen.2008.05.007
- Peters OA, Gluskin A, Weiss R, Han J. An in vitro assessment of the physical properties of novel HyFlex nickel-titanium rotary instruments. Int Endod J. 2012;45(11):1027-1034. doi:10.1111/j.1365-2591.2012.02067.x
- Yared G. Canal preparation using only 1 NiTi rotary instrument: preliminary observations. Int Endod J. 2008;41(4):339-344. doi:10.1111/j.1365-2591.2007.01351.x
- Plotino G, Ahmed HMA, Grande NM, Cohen S, Bukiet F. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part II: properties and effectiveness. J Endod. 2015;41(12):1939-1950. doi:10.1016/j.joen.2015.08.018
- De-Deus G, Leal Vieira VT, Nogueira da Silva EJ, Lopes H, Elias CN, Moreira EJ. Bending resistance and dynamic and static cyclic fatigue life of Reciproc and WaveOne large instruments. J Endod. 2014;40(4):575-579. doi:10.1016/j.joen.2013.10.013
- Plotino G, Rubini AG, Grande NM, Testarelli L, Gambarini G. Cutting efficiency of Reciproc and WaveOne reciprocating instruments. J Endod. 2014;40(8):1228-1230. doi:10.1016/j.joen.2014.01.041
- Ozyurek T, Yilmaz K, Uslu G. Shaping ability of Reciproc, WaveOne Gold, and HyFlex EDM single-file systems in simulated S-shaped canals. J Endod. 2017;43(5):805-809.
- Zuolo AS, Mello JE, Cunha RS, Zuolo ML, Bueno CES. Efficacy of reciprocating and rotary techniques for removing filling material during root canal retreatment. Int Endod J. 2013;46(10):947-953. doi:10.1111/iej.12085
- Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod. 2013;39(2):258-261. doi:10.1016/j.joen.2012.10.025
- Ahn SY, Kim HC, Kim E. Kinematic effects of nickel-titanium instruments with reciprocating or continuous rotation motion: a systematic review of in vitro studies. J Endod. 2016;42(7):1009-1017. doi:10.1016/j.joen.2016.04.002
- You SY, Bae KS, Baek SH, Kum KY, Shon WJ, Lee W. Lifespan of 1 nickel-titanium rotary file with reciprocating motion in curved root canals. J Endod. 2010;36(12):1991-1994. doi:10.1016/j.joen.2010.08.040
- Plotino G, Grande NM, Testarelli L, et al. Cyclic fatigue of Reciproc and Reciproc Blue nickel-titanium reciprocating files at different environmental temperatures. J Endod. 2018;44(10):1549-1552. doi:10.1016/j.joen.2018.06.006
- Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod. 2009;35(11):1469-1476. doi:10.1016/j.joen.2009.06.015
- Kakar S, Dhingra A, Sharma H. Shaping potential of manual NiTi K-file and rotary ProTaper and analyzing the final outcome of shaped canals using CT. J Contemp Dent Pract. 2013;14(3):451-455. doi:10.5005/jp-journals-10024-1343
- da Frota MF, Espir CG, Berbert FL, et al. Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems. J Oral Sci. 2014;56(4):269-275.
- Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43(8):1360-1363. doi:10.1016/j.joen.2017.03.036
- Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold nickel-titanium instruments. J Endod. 2016;42(10):1536-1539. doi:10.1016/j.joen.2016.06.019
- Goo HJ, Kwak SW, Ha JH, Pedullà E, Kim HC. Mechanical properties of various heat-treated nickel-titanium rotary instruments. J Endod. 2017;43(11):1872-1877. doi:10.1016/j.joen.2017.05.025
- Elnaghy A, Elsaka S. Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments. Clin Oral Investig. 2018;22(2):1433-1437. doi:10.1007/s00784-017-2245-5
Tables
Table 1. Number of cyclic failure (NCF) and fractured lengths (FL) (mean ± standard deviation)
Different superscript letters indicate significant differences between groups (P
Additional Information
Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.
Rights and Permissions
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/
About This Article
How to Cite This Article
İhsan Furkan Ertuğrul, Samet Tosun. Comparison of the cyclic fatigue resistance of the original reciproc files with equipollents. Ann Clin Anal Med 2024;15(3):165-168. doi:10.4328/ACAM.22025
Publication History
- Received:
- 26.10.2023
- Accepted:
- 27.11.2023
- Published Online:
- 09.01.2024
- Printed:
- 01.03.2024