False positivity of ultrasonographic lung sliding sign while verifying success in endotracheal tube positioning

False positivity of ultrasonographic lung sliding sign

Abstract

A 47-year-old patient who experienced cardiac arrest following a motor vehicle collision was brought to the emergency department. The patient was intubated with an endotracheal tube (ETT); however, breath sounds could not be heard adequately on auscultation. During ventilation with a bag-valve device, pleural sliding was observed on lung ultrasonography (Figure 1), whereas simultaneous capnography showed that the end-tidal carbon dioxide level did not confirm successful intubation. The patient was therefore extubated and reintubated. The position of the ETT was confirmed by auscultation, capnography, and visualization of pleural sliding (Figure 2). The patient responded to cardiopulmonary resuscitation and was admitted to the intensive care unit. Thoracic computed tomography showed no pneumothorax in either lung.
Determining the position of the ETT after endotracheal intubation (ETI) is critically important in emergency departments. Although several methods can be used to confirm successful ETI, an ideal method has not yet been established 1. Lung auscultation, chest radiography, and capnography are commonly used in daily practice 2. Studies have shown that bilateral pleural sliding observed using time-motion mode on lung ultrasonography is highly effective in confirming successful ETI and saves time, particularly compared with chest radiography 3.
Although this method has yielded highly favorable results, it is important to recognize conditions that may cause false-negative or false-positive findings. Pleural sliding may produce false-negative results in patients with subcutaneous emphysema or bilateral pneumothorax. It should also be remembered that in patients with esophageal intubation, as in our case, increased air within the stomach may increase intrathoracic pressure and produce a false-positive pleural sliding finding.

Additional Information

Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.

Rights and Permissions

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/

About This Article

How to Cite This Article

Ümit Kaldırım, Salim Kemal Tuncer, Yusuf Emrah Eyi. False positivity of ultrasonographic lung sliding sign while verifying success in endotracheal tube positioning. J Clin Anal Med 2015;6(1):139-139. doi:10.4328/JCAM.2210

Publication History

Received:
06.12.2013
Accepted:
12.12.2013
Published Online:
01.01.2015
Printed:
01.01.2015