Information about bottom of iceberg of ammonia measurements in human plasma: evaluation of uncertainty

Uncertainty of plasma ammonia measurement

Abstract

AimUncertainty of measurement (UM) defines the distribution of quantity values attributed to a measurand. The clinician assesses how much of the reported test result reflects its true value. UM for plasma ammonia was estimated according to the International Organization for Standardizairton (IOS ISO is actually the same organization as IOS. 15189) requirements in our laboratory.MethodPlasma Ammonia of UM was calculated in accordance with The Guide to The Expression of Uncertainty of Measurement (GUM) and European Analytical Chemistry (EURACHEM) principles. Laboratory reproducibility was estimated with internal quality control (IQC), while external quality assessment (EQA) results were used to estimate bias and bias uncertainty. Uncertainity of reagents and calibrators was similarly determined. Using this data, including standard uncertainty, is combined with expanded uncertainty, and was also determined for ammonia.ResultsThe expanded uncertainty (k = 2) of ammonia was determined as 14.72 % (95% confidence interval).ConclusionAmmonia is a sensitive test which can be easily affected by preanalytcal errors; thus, it is important that the report is comprised of all analytical uncertainity factors for ammonia. Reporting UM for ammonia answered some questions (e.g., ‘How effective are the analytical sources in the analysis of ammonia?’ and ‘What is the true value of blood ammonia?’). This study may be a prime UM example of ammonia’s function in terms of the literature.

Keywords

plasma ammoniauncertaintyinternal quality controlexternal quality controlwithin-laboratory reproducibility

Additional Information

Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.

Rights and Permissions

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/

About This Article

How to Cite This Article

Fatma Ceyla Eraldemir. Information about bottom of iceberg of ammonia measurements in human plasma: evaluation of uncertainty. J Clin Anal Med 2019;10(1):93-98. doi:10.4328/JCAM.5949

Publication History

Received:
26.06.2018
Accepted:
10.07.2018
Published Online:
11.07.2018
Printed:
01.01.2019