Skip to content

Evaluation of analytical quality of cardiac biomarkersin the emergency laboratory by sigma metrics

Analytical quality of cardiac biomarkers

Original Research doi:10.4328/JCAM.6003 Published: January 1, 2019

Authors

Affiliations

1Department of Biochemistry, School of Medicine, Kocaeli University, Kocaeli, Türkiye.

Corresponding Author

Abstract

AimThe analytic quality of cardiac biomarkers were investigated consecutive six months by sigma metric method in our emergency laboratory. Total allowable error ratio (TEa%)’s of AAB, BV, RCPA, Ricos, and Rilibak were used for calculation. Sigma levels are compared and used to decide which TEa% is appropriate for our laboratory for more accurate results.
MethodSigma levels were calculated for cardiac biomarkers which include Troponin I (cTnI), Troponin T (cTnT), CKMB mass, Myoglobin (Mb) and NT-proBNP in our emergency laboratory department between December 2017 and May 2018. The internal quality control (IQC) and external quality control (EQC) assessment results and TEa%’s of AAB, BV, RCPA, Ricos, and Rilibak were used to calculate sigma metrics. The sigma metrics for tests were calculated by “Sigma = (TEa% − Bias%) / CV%” formula.
ResultsConsidering different TEa% ‘s, it is evaluated that CKMB mass sigma level is at the “world-class quality”. On the contrary, cTnT sigma level is found to be at the level of “poor quality”. For AAB, BV, RCPA, Ricos and Rilibak, different sigma levels are observed.
ConclusionDue to using different TEa%’s for each test, different sigma levels were determined. On the other hand, because of the “poor quality” level of cTnT sigma value, decision is taken for the improvement of cTnT in our laboratory. In addition, it is observed that there is no specified TEa% for whole blood samples. Therefore, it is concluded that, for more accurate and consistent evaluations, specified matrix of TEa% values are required for whole blood samples.

Keywords

six sigma analytical quality management emergency units laboratory markers cardiac biomarkers

Declarations

Additional Information

Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.

Rights and Permissions

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/

About This Article

Received:
August 13, 2018
Accepted:
August 28, 2018
Published Online:
September 4, 2018
Printed:
January 1, 2019