Skip to content

Annals of Clinical and Analytical Medicine

E-ISSN: 2667-663X · Monthly · English

Retrieval of a stuck coronary stent with a micro snare: a modified employment of a familiar device

Retrieval of a stuck coronary stent

Abstract

Considering percutaneous coronary interventions, there are various complications. Stent stuck inside the coronary artery is a rare but deadly condition. The stent is often unopened so it behaves like a foreign body. Urgent withdrawal of the material is crucial to prevent further complications like acute coronary syndrome, progression to open cardiac surgery and finally death. There are some methods and devices for this purpose. In this case, modified employement of a micro snare for the retrieval of an unopened stuck coronary stent is presented.

Keywords

stuck stentmicro snareretrievaltechnique

Additional Information

Publisher’s Note
Bayrakol MP remains neutral with regard to jurisdictional and institutional claims.

Rights and Permissions

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). To view a copy of the license, visit https://creativecommons.org/licenses/by-nc/4.0/

About This Article

How to Cite This Article

Ahmet Karakurt, Hamit Serdar Başbuğ, Abdurrezzak Börekçi, Macit Bitargil. Retrieval of a stuck coronary stent with a micro snare: a modified employment of a familiar device. J Clin Anal Med 2015;5(Suppl 3):375-378. doi:10.4328/JCAM.3250

Publication History

Received:
19.01.2015
Accepted:
04.02.2015
Published Online:
04.02.2015
Printed:
04.02.2015